Phoenix 2924032 MACX MCR-EX-SL-IDSI-I-SP Central unit
Brand: PHOENIX Model number:2924032 MACX MCR-EX-SL-IDSI-I-SP
Country of origin:Germany Product weight:0.55kg
HS code:8517623990
Product Details:
Product Dimensions:
The Phoenix Contact Central Unit operates as an embedded programmable logic controller or central processor within modular automation systems such as the Inline or Axioline series. It houses a high-performance embedded microprocessor dedicated to running deterministic control tasks, managing fieldbus and Ethernet communication interfaces, and reading or writing signals from connected I/O terminals. Designed for compact panel installation, it provides direct DIN rail mounting and integrates seamlessly with standard industrial communication protocols such as PROFINET, Modbus TCP, EtherNet/IP, and INTERBUS. The unit processes input data collected across the local system bus, executes user-defined control programs, and transmits output commands with high precision and low latency.
Processor System: High-performance 32-bit embedded industrial microprocessor optimized for deterministic control logic execution.
Program Memory: Non-volatile onboard Flash memory for application program storage, supplemented by internal RAM for active data processing.
System Bus Architecture: High-speed local bus connection supporting direct module-to-module communication across connected I/O slices.
Network Interfaces: Integrated Ethernet interfaces supporting industrial protocols including PROFINET RT/IRT, Modbus TCP, and EtherNet/IP.
Serial Interfaces: Optional RS-232, RS-422, or RS-485 interfaces for point-to-point communication or legacy device integration.
Supply Voltage: 24 VDC nominal operating voltage range with built-in reverse polarity and surge protection.
Operating Temperature: Industrial ambient operating temperature range from -25°C to 60°C.
Storage Temperature: Storage temperature range spanning -40°C to 85°C.
Permissible Humidity: 5% to 95% relative humidity, non-condensing operation.
Diagnostic Indicators: Front-facing LED status indicators for power supply, system health, bus activity, force modes, and user-configurable error status.
A key advantage of the Phoenix Contact Central Unit is its modular design, allowing easy scalability to match precise application needs without unnecessary hardware costs.
Its high-speed local bus communication ensures extremely fast cycle times and minimal latency, enabling accurate real-time control in demanding automated processes.
The inclusion of standard open communication protocols simplifies integration with third-party automation components, operator interfaces, and enterprise software systems.
Its robust industrial build, vibration resistance, and wide operating temperature range ensure long-term stability and high system availability in harsh industrial environments.
Engineers benefit from user-friendly programming environments compliant with IEC 61131-3 standards, which streamline software development, commissioning, and system maintenance.
System designers must ensure stable 24 VDC power distribution with proper power supply sizing and noise suppression to prevent unintended system resets or communications interruptions.
It is critical to observe proper grounding and shielding practices for all connected fieldbus and network cables to protect the central processing hardware against electromagnetic interference.
Modules must be powered down before making physical changes to the local bus assembly unless explicit hot-swap functionality is supported by the specific model variant.
Firmware updates and application program transfers should only be performed using authorized Phoenix Contact engineering tools to avoid memory corruption or configuration locks.
Proper airflow and clearance around the central unit cabinet must be maintained to prevent internal thermal overload during continuous high-load operation.
Phoenix Contact Central Units are widely deployed across various sectors requiring dependable real-time control and scalable automation solutions.
Factory Automation and Assembly Lines: Controlling automated assembly machines, material handling conveyors, robotic cell interfaces, and packaging equipment.
Process Automation and Utilities: Managing water treatment facilities, pump stations, chemical dosing units, and environmental monitoring networks.
Machine Building and OEMs: Serving as the dedicated master controller for custom machinery, textile equipment, paper processing machines, and CNC auxiliary systems.
Building Infrastructure and Energy Management: Monitoring power distribution panels, controlling HVAC systems, and managing smart lighting networks in industrial facilities.
Transportation and Infrastructure: Managing signaling systems, tunnel ventilation control, remote telemetry units, and highway infrastructure monitoring.

We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
Phoenix2866763
PhoenixPSM-EG-RS232/TTY-P/2K
Phoenix2320500
PhoenixQUINT-PS-100-240AC/24DC/2.5
Phoenix2868567
Phoenix2864176
PhoenixPSM-ME-RS232
PhoenixMCR-VAC-UI-0-DC
Phoenix7400165-510
PhoenixUK 5-HESI
Phoenix2700718
Phoenix2868596
Phoenix2964005
Phoenix2708559
PhoenixQUINT4-DIODE/12-24DC/2X20/1X40
PhoenixQUINT-PS/1AC/24DC/20
Phoenix2961105
PhoenixTRIO-PS/3AC/24DC/10
Phoenix2814508
Phoenix2938840
PhoenixQUINT-PS-100-240AC/24DC/20-2938620
PhoenixQUINT-PS/1AC/24DC/20-2910588
PhoenixWLAN5100
PhoenixPS/1AC/24DC/480W/EE
Phoenix2966472
Phoenix2938879
PhoenixQUINT-PS-100-240AC/24DC/10
Colour:new Warranty: 12 months
Lead Time:3-day working day Price: Please contact us
Shipping Port: Xiamen, China Payment:T/T
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Our service:

Fast delivery, and can be used with your express account.

Competitive Price

Free Shipping

One-year warranty